Error performance, A.4.1 error performance – Comtech EF Data SNM-1002 User Manual
Page 147
SNM-1002 LinkSync
Modem
Revision 2
Remote Control Operation
MN/SNM1002.OM
A–21
Interface
Receive Side
Status
Command:
Response:
UNFL_xxx'cr'
OVFL_xxx'cr'
RXD_xxx'cr'
FBER_xxx'cr'
BWA_xxx'cr'
CLK_xxx'cr'
PLL_xxx'cr'
DMUX_xxx'cr'
2047_xxx'cr'
BUFF_xxx'cr'
INS_xxx'cr'
RAC1_xxx'cr'
RAC2_xxx'cr'
CONF_xxx'cr'
SFLT_xx'cr''lf']
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Data Loss/AIS (OK/FLT)
Frame BER (OK/FLT)
Receive Backward Alarm (OK/FLT)
Selected Buffer Clock Activity (OK/FLT)
Buffer Clock PLL Lock (OK/FLT)
Demux Lock (OK/FLT)
2047 Pattern Lock Detect (OK/FLT)
Buffer Full (OK/FLT)
D&I Insert (OK/FLT)
Receive Audio Clip Channel #1 (OK/FLT)
Receive Audio Clip Channel #2 (OK/FLT)
Configuration (OK/FLT)
Number of Stored Faults Logged (0 to 10)
Common
Equipment
Status
Command:
Response:
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
ST_xxx'cr'
MODE_xxxxxx'cr'
SFLT_xx'cr''lf']
Monitor & Control Module (OK/FLT)
Data Interface/Overhead Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Self Test (OK/FLT)
Mode (LOCAL or REMOTE)
Number of stored faults logged (0 to 10)
The common equipment status command causes
a block of data to be returned which indicates the
status of the common equipment.
A.4.1 Error
Performance
Raw BER
Command:
Response:
Where:
x = < or > (data modifier to indicate that the error
rate is less than or greater than the returned
value).
m.m = 1.0 to 9.9 (error rate mantissa).
ee = 1 to 99 (error rate exponent).
Notes:
1.
The 'x' (< or >) parameter is only
returned if the error rate has exceeded the
computational resolution of the system.
2.
'No Data' is returned if the error rate
cannot be calculated.
3.
'Sampling' is returned if not enough data
is currently available to calculate the error rate.