Comtech EF Data SNM-1002 User Manual
Page 166

SNM-1002 LinkSync
Modem
Revision 2
Remote Control Operation
MN/SNM1002.OM
A–40
Change
Status
Command:
Response:
Where:
The 'x' character is defined as follows:
'@' = no change since last BCS_ and BCSF_
polls.
'A' = BCS_ response has changed since last
BCS_ poll.
'B' = BCSF_ response has changed since last
BCSF_ poll.
'C' = Both responses have changed since last
BCS_ and BCSF_ polls.
This command indicates that a change has or
has not occurred on either the BCS_ or the
BCSF_ response since the last BCS_ or BCSF_
poll.
Equipment
Type
Command:
Response:
Where:
tttttttt = Equipment type.
xxx.yyy.zzz = Software version.
Monitor &
Control
Firmware
Information
Command:
Response:
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
DATA ROM
Firmware
Information
Command:
Response:
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
Note: If Dash number is not used, '-dd' will be
reported.
Boot M&C
Firmware
Information
Command:
Response:
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).