7 index f607 dpo inputs device – BECKHOFF EP9214-0023 User Manual
Page 79
Comissioning and Configuration
4.6.2.1.7
Index F607 DPO Inputs Device
Index
Name
Meaning
Data type
Flags
Default
F607:0
DPO Inputs Device
UINT8
RO
0x19 (25
dec
)
F607:01
Temperature Warning
A temperature of about 80°C
has been reached
boolean
RO
0x00 (0
dec
)
F607:02
Temperature Error
A critical temperature of about
85°C has been reached, the
outputs will be switched off. The
bit must be reset by a Global
Reset (F707:04) or by a voltage
reset. No output can be
switched on if the error bit is
set.
boolean
RO
0x00 (0
dec
)
F607:03
Us Warning
Us is less than 21.5 V, no fur-
ther outputs can be switched
on.
boolean
RO
0x00 (0
dec
)
F607:04
Us Error
Us is less than 19 V, all Us out-
puts will be switched off. The bit
must be reset by a Global Re-
set (F707:04) or by a voltage
reset. No Us output can be
switched on if the error bit is
set.
boolean
RO
0x00 (0
dec
)
F607:05
Up Warning
Up is less than 21.5 V, no fur-
ther outputs can be switched
on.
boolean
RO
0x00 (0
dec
)
F607:06
Up Error
Up is less than 19 V, all Up out-
puts will be switched off. The bit
must be reset by a Global Re-
set (F707:04) or by a voltage
reset. No Up output can be
switched on if the error bit is
set.
boolean
RO
0x00 (0
dec
)
F607:07
Global Error Bit
One of the error bits of the four
channels or F607:02 or F607:04
or F607:06 is set
boolean
RO
0x00 (0
dec
)
F607:08
Sum Current Warning
Sum current monitoring has de-
sected a peak current
boolean
RO
0x00 (0
dec
)
F607:09
Sum Current Error
Sum current monitoring has de-
sected an over current. All out-
puts are switched off
boolean
RO
0x00 (0
dec
)
F607:0C
Reset Input
Us is less than 21.5 V, no fur-
ther outputs can be switched
on.
boolean
RO
0x00 (0
dec
)
F607:0F
TxPDO State
boolean
RO
0x00 (0
dec
)
F607:10
TxPDO Toggle
boolean
RO
0x00 (0
dec
)
F607:11
Current Us
Sum current of the module at
Us
INT16
RO
0x0000 (0
dec
)
F607:12
Current Up
Sum current of the module at
Up
INT16
RO
0x0000 (0
dec
)
F607:13
Voltage Us
Voltage at input Us
INT16
RO
0x0000 (0
dec
)
F607:14
Voltage Up
Voltage at input Up
INT16
RO
0x0000 (0
dec
)
F607:15
Temperature
Internal temperature of power
stage
INT16
RO
0x0000 (0
dec
)
F607:16
Peak Value 1
Extended diagnosis
INT16
RO
0x0000 (0
dec
)
F607:17
Peak Value 2
Extended diagnosis
INT16
RO
0x0000 (0
dec
)
F607:18
Timestamp 1
UINT64
RO
F607:19
Timestamp 2
UINT64
RO
EP9214-0023 and EP9224-0023
79
Version 2.0.0