ATEIS UAPg2 User Manual
Page 52

UAPG2 MANUAL
Version EN.24
52
Clear Remote IP
Opens the Parameter setting window (floating window)
Clear the IP addresses of the remote devices (PPM, URC)
connected to the selected UAPG2(s).
If you add new remote device or change something in the system
you may have to clean all IP addresses and re-give addresses
(Search process in the remote list window: sheet 39).
Click on Delete several time
Clear MCU Data
Opens the Clear MCU table window (floating window)
Clean the memory (design) of the connected UAPG2.
This feature is useful when the UAPG2 have strange behaviours due to a error during data transfers
or an old improper design.
VR Calibration
Opens the VR Calibration window (floating window)
Here you calibrate all the remote potentiometer (Variable Resistors)
connected in the control inputs (defined as analog inputs) and the 8
front knobs of the UAPG2.
Simply choose the UAPG2 of the system and the control input (or the
front knob) then put it at the minimum and click on [Minimum]’s button
then put the potentiometer (or the front knob) to the maximum and
press the [Maximum]’s button. After that switch off/on the UAPG2 and
the potentiometers are calibrated.