Output – ATEIS UAPg2 User Manual
Page 176

UAPG2 MANUAL
Version EN.24
176
Output
Control the output signals parameters and monitor it.
The analogue output modules represent the physical analogue outputs accessible on the rear panel
of the UAPG2. There are four separate modules for use with each of the audio board slots A, B, C and
D. Analogue input and output modules are added automatically to the DSP window of the relevant
processor by defining their module configuration at the time you create them and should not be
altered.
The main control window of the analogue output module is opened by a double click on the icon in
the UAPG2 design window and appears like this:
Analogue Output Parameters
Parameter
Range
Comment
Clip
LED, lit red
Indicates channel level above chosen 'Clip Threshold (dB)'.
Volume (dB)
-90.0 to
+20.0 dB
Meter showing the channel level.
Mute
On/Off
Mutes or un-mutes the output channel; LED, lit red with channel
muted.
Signal
LED, lit blue
@ -30 dB
Indicates audio signal presence above 30 dB.
Level (dB)
-90.0 to
+20.0 dB
Signal output level of the module
Clip Threshold
-20.0 to
+20.0 dB
Sets the threshold of the Clip indicator.