ATEIS UAPg2 User Manual
Page 220

UAPG2 MANUAL
Version EN.24
220
Parameter
Range
Comment
Ambiant noise
Meter
AGC Level
Meter
Display the current compensation gain
Hold time
1 to 5 sec
Holding time between when the P.M. signal passes below the mode
threshold and the end of the paging activity.
Paging activity
Light up when the paging is active.
(when P.M. is above the mode threshold)
Decrease Zone
Indicates that the AGC gain is decreasing
Dead Zone
Indicates that the AGC is not changing
Increase Zone
Indicates that the AGC gain is increasing
Fast Increase Zone
Indicates that the AGC gain is increasing fast
Sensing Mic Level
Indicator
/RMS
Show the input level of the sensing microphone
C/Sensing Mic Level
Indicator
Show the input level of the sensing microphone through the
calibration transfer function
Output Level
Indicator
/RMS
Show the output level
Differential Level
Indicator
Difference between the Output level and C/Sensing Mic level.
For the procedures and use, please see
Use the Automatic Gain Control
.