Auto noise gain – ATEIS UAPg2 User Manual
Page 219

UAPG2 MANUAL
Version EN.24
219
Auto Noise Gain
Adjust the audio level of the paging input (P.M.) depending of the ambient noise.
The ambient noise is measured with a sensing microphone connected to the sensing microphone
input (S.M.). Our advice is to use the sensing microphone MSN (Ateïs), but you can also use another
one.
•
S.M: sensing microphone input
•
P.M: paging input
Parameter
Range
Comment
Calibration
Button
Click on to start the automatic calibration procedure
Calibration
Lit all along the calibration procedure
Calibration
Lit when the A.N.G is properly calibrate
Over
Indicates the calibration result:
The white noise level needed is over the range.
A pop-up window will shows you what to do.
Under
Indicates the calibration result:
The white noise level needed is under the range.
A pop-up window will show you what to do :
Response speed
Selector
Select here the reaction speed of the A.N.G.
That's means the speed to adapt the P.M. audio level depending of
the ambient noise.
Min Gain
-15 to 0 dB
The minimum AGC level compensation
Max Gain
0 to 15 dB
The maximum AGC level compensation
Sampling time
0.5 to 60 sec
Determine the period time between two ambient noise measures
Noise generator
Meter
White noise level, automatically Adjusted by the calibration