ATEIS UAPg2 User Manual
Page 181

UAPG2 MANUAL
Version EN.24
181
Automixer Parameters
Parameter
Range
Comment
Mute
On/Off
Mutes or un-mutes the input channel.
Invert
0°/180°
Inverts the polarity of the input channel.
Solo
On/Off
Solos the input channel. (the channel goes directly to the output)
Gate On
LED, lit green
Shows activation status of the input channel.
Level (dB)
-90.0 to
+20.0 dB
Adjusts the level of the output channel.
Manual Mode
On/Off
Only used in manual mode (see "Manual/Automatic")
It allows manual channel activation.
Automatic Mode Priority Level
1 to (n)
Sets the priority level of the channel. 1 is the most priority.
Output mute
On/Off
Mutes or un-mutes the module's output.
Output level (dB)
-90.0 to
+20.0 dB
Sets the module's output level.
Threshold (dB)
-90.0 to
+20.0 dB
Sets the threshold for channel activation.
Hold time (s)
0 to 10 s
Sets a hold time for the gate deactivation.
Attenuation Response time
(ms)
10 ms to 10.0 s Sets a pre delay time for automatic attenuation.
That's means the transition time of the attenuation when a channel is added or
removed.
Background threshold (%)
0.0 to 100.0%
Sets how the input signal is interpreted to open a gate.
The background level will increase the input activation level.
NOM attenuation step (dB)
0.0 to 6.0 dB
Sets the amount of attenuation to be applied each time the number of activated
channels increases.
NOM attenuation max (dB)
0.0 to 100.0 dB
Limits the amount of attenuation to be applied.
Attn. Gain (dB)
-100.0 to
+20.0 dB
Indicates the amount of current gain reduction
Last Mic. On
On/Off
Enables the last mic on function.
If activate, even if there is no audio on the inputs, one channel will stay open. (see
"Last Mic.On designated" parameter)
Last Mic. On designated
Ch 1 to (n), Last
Mic.
Defines which channel will stay open
(Only if "Last Mic. On" is activated).
Caution the channel will stay open even if it's muted.
Open Mic. Limits
1 to Non Limit
Chooses the maximum number of simultaneously activated channels.
Manual/Automatic
Manual or
Automatic
Select the mode, manual or automatic.
Manual mode : Only manual channel activation (threshold and priority are ignored)
Automatic mode : With priority and threshold channel activation.
NOM attenuation mode
Eq1 or Eq2
Chose here if you want a linear attenuation or a logarithmic attenuation which is more
near of the reality.
Eq1 : (NOM-1) x step (same attenuation for each addicting channel)
Eq2: log2(NOM) x step
On UAPg2 v1.0.3.50, the attenuation doesn't works if mic limit is set to