Gate
The gate allows you to cut off the signal below a chosen threshold.
You can choose between four different gates:
•
Mono
•
With Sidechain
•
Stereo
Gate Mono
The first module within the "Gate" folder is a simple single channel:
The control window of the "Gate - Mono" module is opened by a double click on the component.
Gate Parameters
Parameter
Range
Comment
Mute
Button
Mute the gate's module
Bypass
Button
Switch off the gate's operation
Gate on
LED, lit green
Flash when the gate is active (open)
Thd. (Threshold) (dB)
-60.0 to
+20.0 dB
Sets the threshold level above which the Gate will open.
Response time
0 to 5000 ms
Adjust the time between the level's detection and the beginning of
the Gate operation
Attack time (ms)
0 to 1000 ms
Adjust the fade-in time of the signal when Gate is working.
Hold time
0 to 5000 ms
Adjust the time between the end level's detection and the end of
the Gate operation
Release time (ms)
10 to
10000 ms
Adjust the fade-out time of the signal when Gate is no longer
working
Depth (dB)
-100 to 0 dB
Attenuate the level when the Gate is active.