95

Device ID check error terminates the operation (default

ENABLE)

Programmer provides ID check before each selected action. It compares read ID codes from
device with ID codes defined by device manufacturer. In case of ID error, control program
behaves as follows:

- if item is set to ENABLE, selected action is finished
- if item is set to DISABLE, selected action continues. Control program just writes warning

message about ID error to LOG window.

If enabled, the programmer checks the electronic ID of the programmed chip.

Note 1: Some old chips don't carry electronic ID.
Note 2: In some special cases, several microcontrollers don't provide ID, if copy protection
feature in the chip is set, even if device ID check setting in control program is set to "Enable".

group Command execution:

blank check before programming

(default DISABLE)

erase before programming

(default DISABLE)

verify after reading

(default ENABLE)

verify

(ONCE, TWICE)

verify options

(nominal VCC +/-5%

nominal VCC +/-10%
VCCmin - VCCmax)

group Target system power supply parameters

This group is available in ISP mode for some types of devices. It contains following settings:
Enable target system power supply - enables supplying of target system from programmer.
Supply voltage for target system is switched on before action with programmed device and is
switched off after action finished. If Keep ISP signals at defined level after operation is
enabled, then programmer will switch off supply voltage after pull-up/pull-down resistors are
deactivated.

Voltage - supply voltage for target system. Supply voltage range is from 2V to 6V.
Note: The voltage value given to target system depends also on current flowing to target
system. To reach exact voltage supply for target system, the proper Voltage and Max. current
values has to be defined. The Max. current value specified has to be as exact as possible
equal to real current consumption of target system.

Max. current - maximum current consumption of powered target system. Current
consumption range is from 0 to 300mA

Voltage rise time - determines skew rate of rising edge of target system power supply
voltage (switch on supply voltage).

Target supply settle time - determines time, after which must be supply voltage in target
system stabilized at set value and target system is ready to any action with programmed
device.

Voltage fall time - determines skew rate of falling edge of target system power supply
voltage (switch off supply voltage).