The next function of statistics is Count down. Count down allows checking the number of
device operations, and then number of devices, on which device operations have to be done.
After each successful device operation the value of count down counter is decremented.
Count down has user defined start number of devices to do. When count down value reach
zero, it means, specified number of devices is complete and user message about complete
count down will be displayed.

Statistics dialog contains following options:

Check boxes Program, Verify, Blank, Erase and Read define operations, after which
statistics values increment.

Any selected and performed device operation will increment the Total counter and one of
Success or Failure counters depending on device operation result (success or failure).
A combination of partial operations is counted as one operation only. For example, a Read
operation including Verify after Read is one operation. A Program operation including Erase
and/or Verify operations is counted as one operation.

Check box Count down sets Count down activity (enable or disable). Edit box following the
Count down check box defines initial number of count down counter, from which count down
starts.

Statistics dialog can be also opened by pressing right mouse button on Statistics panel and
clicking displayed item Statistics.

Statistics dialog contains seven statistics values – Success, Operational failure, Adapter
test failure
, Insertion test failure, ID check failure, Other failure (prog. SW, HW) and
Total.

Meaning of the values is:

Success

number of operations which where successfully completed

Operational failure

number of operations which where not successfully
completed due to error of device

Adapter test failure

number of operations which where not successfully
completed due to incorrect programming adapter

Insertion test failure

number of operations which where not successfully
completed due to incorrect position of device in
programming adapter

ID check failure

number of operations which where not successfully
completed due to incorrect ID code read from device

Other failure (prog. SW, HW) number of operations which where not successfully

completed due to hardware error of programmer or control
software error

Total

- number of all operations

Actual statistics values are displaying in main window of control program in Statistics panel.

Statistics panel contains four statistics values – Success, Operational failure, Other
failure
, Total and two Count down information values Count down and Remains.