Programmer / selftest plus, Programmer / self test isp connector – Dataman 40Pro User Manual
Page 125
PG4UW
125
Programmer / Selftest plus
Command executes a selftest plus of current programmer using diagnostic POD, which is
included in standard delivery of programmer.
Recommendations how often run Selftest plus you can find at Maintenance section.
Programmer / Self test ISP connector
Command executes a selftest of ISP connector of current programmer using diagnostic POD
for ISP connectors.
Diagnostic POD for ISP connectors is necessary to use for testing 6 and 10-pin ISP
connectors of programmers. Diagnostic POD for ISP connectors is available as optional
accessories for programmers with 6-pin and 10-pin ISP connector (DATAMAN-40PRO).
Schematic of Diagnostic POD for ISP connector (if you are in hurry):
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
J1
DIP40 to ZIF socket
ZIF1
ZIF2
ZIF3
ZIF4
ZIF5
ZIF6
ZIF7
ZIF8
ZIF9
ZIF11
1
2
3
4
5
6
7
8
9
10
J2
HARTING 09185106324
1
2
3
4
5
6
J3
HARTING 09185066324
1
2
HR1A 47R
3
4
HR1B 47R
5
6
HR1C 47R
ZIF7
ZIF4
ZIF9
ZIF1
ZIF2
ZIF3
ZIF5
ZIF6
ZIF8
ZIF11
ZIF2
ZIF3
ZIF4
ZIF5
ZIF6
ZIF8
Sequence for testing 6 pins ISP connector:
1. Insert Diagnostic POD for ISP connectors into ZIF socket of the programmer. Diagnostic
POD for ISP connectors must be inserted as 40 pins device.
2. Interconnect 6 pins connector of Diagnostic POD for ISP connectors with an ISP
connector of the programmer with an ISP cable, included in programmer delivery
package. Be sure that pins are interconnected properly (i.e. 1-1, 2-2, ..., 6-6).
3. Run selftest of ISP connector in PG4UW (Programmer / Selftest ISP connector…).
Sequence for testing 10 pins ISP connector:
1. Insert Diagnostic POD for ISP connectors into ZIF socket of the programmer. Diagnostic
POD for ISP connectors must be inserted as 40 pins device.
2. Interconnect 10 pins connector of Diagnostic POD for ISP connectors with an ISP
connector of the programmer with an ISP cable, included in delivery programmer
package. Be sure that pins are interconnected properly (i.e. 1-1, 2-2, ..., 10-10).
3. Run selftest of ISP connector in PG4UW (Programmer / Selftest ISP connector…).