beautypg.com

Buffer / erase, Buffer / fill random data – Dataman 40Pro User Manual

Page 87

background image

PG4UW

87

Address

Original

Data

Swap 2-bytes

inside 16-bit

words

Swap 4-bytes

inside 32-bit

words

Swap

nibbles

inside bytes

Mirror bits

inside

bytes

0000h

b0

b1

b3

b0n

b0m

0001h

b1

b0

b2

b1n

b1m

0002h

b2

b3

b1

b2n

b2m

0003h

b3

b2

b0

b3n

b3m

0004h

b4

b5

b7

b4n

b4m

0005h

b5

b4

b6

b5n

b5m

0006h

b6

b7

b5

b6n

b6m

0007h

b7

b6

b4

b7n

b7m

b0, b1, b2, ... means original buffer byte values from addresses 0, 1, 2, ...
b0n, b1n, b2n, ... means nibble-swapped original bytes b0, b1, b2, ... by following rules:

Original Byte bits

bit

7 bit

6 bit

5 bit

4 bit

3 bit

2 bit

1 bit

0

Nibble-swapped

Byte

Bits bit

3 bit

2 bit

1 bit

0 bit

7 bit

6 bit

5 bit

4

Original Byte bits

bit

7 bit

6 bit

5 bit

4 bit

3 bit

2 bit

1 bit

0

Mirrored Byte Bits

bit

0 bit

1 bit

2 bit

3 bit

4 bit

5 bit

6 bit

7

Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note: Address history values are common for all buffer data manipulation dialogs.

Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.

Buffer / Erase

If this command is selected, the content of the buffer will be filled with topical blank character.

Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note: Address history values are common for all buffer data manipulation dialogs.

Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.

The reserved key will bring out this menu from any menu and any time.

Buffer / Fill random data

If this command is selected, the content of the buffer will be filled with random data.

Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note: Address history values are common for all buffer data manipulation dialogs.