Altera JNEye User Manual
Page 31

Supply Voltage
For supported devices, you can choose the supply voltage. In JNEye 15.0, the Arria 10 GX/SX/GT
transmitter model provides the following supply voltages:
• Default-BP—Supply voltage for backplane applications that have a dependency on the data rate
setting
• Default-C2C—Supply voltage for chip-to-chip applications that have a dependency on the data rate
setting
• 0.9 V (Arria 10 GX/SX/GT)
• 1.0 V (Arria 10 GX/SX/GT)
• 1.1 V (Arria 10 GT)
V
cm
V
cm
is the common voltage of the transmitted signal.
PVT
Select the process, voltage, and temperature (PVT) models for the selected transmitter device. PVT model
support varies depending on device type, device data availability, and model coverage. A message is
shown on the Transmitter tab page to indicate the PVT model coverage. Transmitter PVT model coverage
and conditions are shown in the following table.
Table 2-6: Transmitter PVT Model Coverage
Transmitter Type
Waveform PVT Model
Jitter/Noise PVT Model
Stratix V GX
Typical
Process: Typical/Fast/Slow Voltage:
Typical/High/Low Temperature:
–40°C to 100°C
Arria V GZ
Typical
Process: Typical/Fast/Slow Voltage:
Typical/High/Low Temperature:
–40°C to 100°C
Stratix V GT
Typical
Process: Typical/Fast/Slow Voltage:
Typical/High/Low Temperature: 0°C
to 100°C
Arria 10 GX/SX
Typical/Fast/Slow
Typical
Arria 10 GT
Typical/Fast/Slow
Typical
IBIS-AMI
Provide by IBIS-AMI
model
Provide by IBIS-AMI model
Custom
None
None
PCI-Express 8GT
None
None
JNEye to Quartus II Parameter Translation for Arria 10 GX/SX/GT Transmitters
The following table provides a translation from JNEye Arria 10 GX/SX/GT transmitter parameter names
to the equivalent Quartus II parameter names. Use the Quartus II software to transfer optimum device
settings from a JNEye simulation to an actual device configuration.
UG-1146
2015.05.04
Transmitter Setting
2-25
Functional Description
Altera Corporation