beautypg.com

Changing array ownership – StorCase Technology CSI-to-SCSI Single & Dual RAID User Manual

Page 58

background image

Dual RAID Module User's Guide - Rev. A03

StorCase Technology, Inc.

Configuration

45

4.

Enter a name for the array and press Enter.
Up to 20 characters (any character, including spaces) can be used.
The system will now confirm the change.

5.

Select Yes and press Enter.

Changing Array Ownership

If using the Active-Active mode, this function allows the user to change the ownership of any

array between the controllers.

Changing ownership lets the user continue using an array without interruption and makes the

array visisble on the controller the user changes it to (the user will no longer see the array

ion the original controller).

To change array ownership:

1.

Select Array Menu from the System Menu and press Enter.
The Select Array screen should now display, along with a list of existing arrays (Figure

19).

2.

Select the desired array and press Enter.
The Array Menu should now display (Figure 20).

3.

Select Switch Array Owner and press Enter.
The system will now confirm your request to change ownership.

4.

Select Yes and press Enter.

5.

Assign a new LUN to each array partition

.