StorCase Technology CSI-to-SCSI Single & Dual RAID User Manual
Page 50

Dual RAID Module User's Guide - Rev. A03
StorCase Technology, Inc.
Configuration
37
6.
Enter a name for the partition and press Enter.
Up to 20 characters (any character, including spaces) can be used. If no name is to
be used, just press Enter (a name may be added or changed later).
The Partition LUN screen should now display (Figure 26).
Figure 26: Partition LUN Screen
7.
Select the LUN for the partition and press Enter.
The LUN displayed is the suggested default LUN assignment.
If the letters OV appear before a LUN, this indicates that the selection overlaps with
a soft LUN, most likely the controller or SAF-TE Environmental Processor (SEP) LUN.
An array at an overlapped LUN may be created, but it will not be seen by the host
system until the controller is rebooted.
NOTE:
Most UNIX, LINUX, and Macintosh operating systems require the controller
LUN to be a higher value than all array LUNs. Before creating the first array,
change the controller LUN to a higher value or choose NONE (best option)
if not using CAPI to manage the arrays. This allows the first array to be
seen at LUN 0.
The system will now confirm the change.
8.
Select Yes and press Enter.