Dual RAID Module User's Guide - Rev. A03

StorCase Technology, Inc.

Appendix C - Troubleshooting

145

Table C-1: POST Diagnostic Errors and Solutions

Diagnostic Failure

Solutions

IFS_58fc

Default hardware register

Replace the controller

1. Check the enclosure for a proper supply

of Vcc and +12V

2. Check for thermal problems in the

enclosure

3. Replace the controller

Default chip set register

Voltage/temperature

Local DRAM memory test

LVDS Bist

PCI configuration verification

Replace the controller

Replace the controller

Replace the controller

SCSI device SCB SRAM

SCSI device scratch RAM

I C chip

2

Replace the controller

Replace the controller

Replace the controller

1. Check the backplane and the enclosure

2. Replace the controller

Replace the controller

Cache memory

Programmable interval timer

Real-time clock chip

Battery

Replace the controller

Replace the controller

1. Check the battery to make sure it is

properly connected

2. Check the battery cable to make sure it

is not broken

3. Replace the battery

4. Replace the controller

FC Diagnostics or

FC Initialization

Check to make sure module is installed

properly