StorCase Technology CSI-to-SCSI Single & Dual RAID User Manual
Page 158

Dual RAID Module User's Guide - Rev. A03
StorCase Technology, Inc.
Appendix C - Troubleshooting
145
Table C-1: POST Diagnostic Errors and Solutions
Diagnostic Failure
Solutions
IFS_58fc
Default hardware register
Replace the controller
1. Check the enclosure for a proper supply
of Vcc and +12V
2. Check for thermal problems in the
enclosure
3. Replace the controller
Default chip set register
Voltage/temperature
Local DRAM memory test
LVDS Bist
PCI configuration verification
Replace the controller
Replace the controller
Replace the controller
SCSI device SCB SRAM
SCSI device scratch RAM
I C chip
2
Replace the controller
Replace the controller
Replace the controller
1. Check the backplane and the enclosure
2. Replace the controller
Replace the controller
Cache memory
Programmable interval timer
Real-time clock chip
Battery
Replace the controller
Replace the controller
1. Check the battery to make sure it is
properly connected
2. Check the battery cable to make sure it
is not broken
3. Replace the battery
4. Replace the controller
FC Diagnostics or
FC Initialization
Check to make sure module is installed
properly