beautypg.com

Dual raid controller module unit panel – StorCase Technology CSI-to-SCSI Single & Dual RAID User Manual

Page 17

background image

4

Introduction

StorCase Technology, Inc.

Dual RAID Module User's Guide - Rev. A03

Dual RAID Controller Module Unit Panel

(Figure 2A)

•

Controller A - Primary RAID controller

•

Controller B - Secondary RAID controller

•

Host Channel 0 (In) - Connects to SCSI Host 0

•

Host Channel 0 (Out) - Connects to LVD/S.E. Multi-mode terminator (or other SCSI

device)

•

Host Channel 1 (In) - Connects to SCSI Host 1

•

Host Channel 1 (Out) - Connects to LVD/S.E. Multi-mode terminator (or other SCSI

device)

•

Disk Channel 1 - Connects to InfoStation I/O module #1

•

Disk Channel 2 - Connects to InfoStation I/O module #2

•

Cache LED (Green) - Provides the following information:

ON =

Indicates that data is in Cache Memory

OFF=

Indicates that data write to disk is complete

•

Fault LED (Red) - Provides a visual indication of error conditions.

•

RS-232 Serial Port (RAID Configuration Port) - Connects to a VT-100/ANSI terminal

via an RJ45-DB9 cable (provided). Refer to section "Configuration" for further

information.

•

LEDs (Figure 2B) - Provide the following information:

Activity

B1 -

ON indicates SCSI Host 1 activity on Controller B

B0 -

ON indicates SCSI Host 0 activity on Controller B

A1 -

ON indicates SCSI Host 1 activity on Controller A

A0 -

ON indicates SCSI Host 0 activity on Controller A

(RESERVED) -

Reserved for future use.

DISABLED -

ON =

RS-232 port is DISABLED.

OFF =

RS-232 port is ENABLED.