Managing the saf-te board, Testing a drive – StorCase Technology CSI-to-SCSI Single & Dual RAID User Manual
Page 138

Dual RAID Module User's Guide - Rev. A03
StorCase Technology, Inc.
Configuration
125
Testing a Drive
This function allows the user to issue a Test Unit Ready (TUR) command to a specific disk drive.
NOTE:
A drive can still respond, even if it is not functioning properly.
To test a drive:
1.
Select Utilities Menu from the System Menu and press Enter.
The Utilities Menu should now display (Figure 45).
2.
Select Drive Utilities Menu and press Enter.
The Drive Utilities Menu should now display (Figure 75).
3.
Select Test Unit Ready and press Enter.
The Select Drive screen should now display.
4.
Select the desired drive and press Enter.
If the TUR was successful, TUR STATUS OK will display.
If the TUR was unsuccessful, a failure message will display.
5.
Press Esc to return to the Drive Utilities Menu.
Managing the SAF-TE Board
The SAF-TE Board is a SCSI device from which the RAID Controller can inquire about
environmental conditions such as temperature, power supply and fan status, and the
presence/absence of disk drives. The RAID controller can also tell the SAF-TE Board about
RAID activities such as drive rebuilds and failed disk drives.
SAF-TE configuration settings are automatically enabled when the controller is installed. No
changes are required to the default configuration settings to support the SAF-TE Board.
The user can control the following SAF-TE Board functions:
Change SAF-TE Board LUN
Change additional SAF-TE Board settings
- Polling Interval
- Temperature sensor status