Dual RAID Module User's Guide - Rev. A03
StorCase Technology, Inc.
Configuration
87
Host Channel
Setting
Available
Modes
Description
Controller LUN
All
The controller has just one LUN that the user can change when
configuring the host channels. The user only needs to assign
a controller LUN if using the Configuration Application Program
Interface (CAPI) to configure the controller over a host channel
via SCSI protocol extensions.
If not using CAPI, the user can set the controller LUN to NONE.
If using CAPI, the user can set the controller LUN from 0-63.
Two options for setting the LUN:
NONE: Use this setting if not using CAPI to configure the con-
troller (change takes effect immediately unless the controller
LUN is currently in use).
Any number between 0-63: Select a specific number if the con-
troller LUN is to remain the same during reboot.
Refer to section
Understanding
LUNs and Viewing
LUN Information
for further informa-
tion.
IFS_83
Table 6: Host Channel Settings (cont'd)
To configure the host channels:
1.
Select Configuration Menu from the System Menu and press Enter.
The Configuration Menu should now display (Figure 31).
2.
Select Host Configuration and press Enter.
The Channel screen should now display.
3.
Select the desired channel to configure and press Enter.
The current setting is marked with an * next to it.
Refer to Table 6 for further information about each setting.
3.
Select the desired setting from each screen and Press Enter.
The system will now confirm the settings.
4.
Select Yes and press Enter.