1 selecting a view, 1 selecting, View – LINK Systems 5100-8 Tonnage & Analog Signal Monitor User Manual
Page 19: Figure 7). this key is only present when

Doc
#:
L-802-1110 Page
17 Rev.
02
Figure 6 shows a four channel screen when viewing data window 1 tonnages. Notice that the major
difference between this screen and that of Figure 5 is the addition of three new parameters and the lack
of a REVERSE TONNAGE softkey.
Forward Tonnage
39.5
Tons
HIGH 150%
LOW 0%
9.8
Tons
HIGH 150%
LOW 0%
10.3
Tons
HIGH 150%
LOW 0%
11.4
Tons
HIGH 150%
LOW 0%
13.7
Tons
Module Status: OK
CHANGE
LOW LIMIT
Angles
Start Ang: 166.0
End Ang: 177.0
DATA WIN
ON/OFF
(
ON
)
CHANGE
ON ANGLE
CHANGE
OFF ANGLE
CHANGE
HIGH LIMIT
k
l m
Stroke
Mode
Single Stroke
Drive
Speed
SPM
SPM
0
Order
Counter
Current Status
Counter OFF
0
0
Program/Run Switch
TOP
Stroke
Speed
Tonnage
Monitor
EXIT
CHANGE
VIEW
GRAPH
BYPASS
SETP
DIAGNOS
LOW LIMITS
ON/OFF
BYPASS
ON/OFF
CONFIGURE
AUTO-SETUP
RESET
FAULT
View
Total
Data Win 1
Low Limit: 9.1
Status OK
CH1 - Left Rear
CH2 - Right Rear
CH3 - Left Front
CH4 – Right Front
High Limit: 13.2
Low Limit: 8.1
Status OK
High Limit: 12.2
Low Limit: 12.0
Status OK
High Limit: 14.8
Low Limit: 8.5
Status OK
High Limit: 11.5
Forward Tonnage
39.5
Tons
HIGH 150%
LOW 0%
9.8
Tons
HIGH 150%
LOW 0%
10.3
Tons
HIGH 150%
LOW 0%
11.4
Tons
HIGH 150%
LOW 0%
13.7
Tons
Module Status: OK
CHANGE
LOW LIMIT
Angles
Start Ang: 166.0
End Ang: 177.0
DATA WIN
ON/OFF
(
ON
)
CHANGE
ON ANGLE
CHANGE
OFF ANGLE
CHANGE
HIGH LIMIT
k
l m
Stroke
Mode
Single Stroke
Drive
Speed
SPM
SPM
0
Order
Counter
Current Status
Counter OFF
0
0
Program/Run Switch
TOP
Stroke
Speed
Tonnage
Monitor
EXIT
CHANGE
VIEW
GRAPH
BYPASS
SETP
DIAGNOS
LOW LIMITS
ON/OFF
BYPASS
ON/OFF
CONFIGURE
AUTO-SETUP
RESET
FAULT
View
Total
Data Win 1
Low Limit: 9.1
Status OK
CH1 - Left Rear
CH2 - Right Rear
CH3 - Left Front
CH4 – Right Front
High Limit: 13.2
Low Limit: 8.1
Status OK
High Limit: 12.2
Low Limit: 12.0
Status OK
High Limit: 14.8
Low Limit: 8.5
Status OK
High Limit: 11.5
Figure 6: Tonnage Monitor Main Screen Showing Data Window 1 Tonnage
In Figure 6, some additional settings in a data window view are:
k) Data Window
On/Off
This determines whether the data window is active. When “On”, the data
window setpoints are enforced from the “Start Angle” to the “End Angle”.
When “Off”, these settings are not used at all and will NOT stop the press.
l) Data
Window
Start Angle
The angle at which the data window setpoints will start to be enforced.
m) Data Window End
Angle
The angle at which data window setpoints stop being enforced.