Dialogic

®

PBX Integration Board User’s Guide

4.2. Siemens ROLM PBX

The ROLM product family includes three generations of ROLM and related
PBXs:

1. The original ROLM

2. IBM ROLM 9751 series

3. Siemens Hicom 300 with the appropriate interface cards

The Dialogic

®

PBX Integration Board emulating the ROLM 400 telephone

can be used with these switches. The ROLM PBXs use digital signaling to
control their station sets and digitized voice.

The Dialogic

®

PBX Integration Board has either four or eight channels that

can be connected directly to a station module in a Siemens ROLM PBX. The
PBX switch has many standard features that are supported by the PBX
Integration Board, such as:

• direct inward dialing (DID)

• speed dialing

• hunt groups

• message waiting indication

• user programmable feature keys

• called/calling number identification

• call forwarding

4.2.1. Siemens ROLM Programming Requirements

There are specific switch programming requirements that apply if using a
Dialogic

®

PBX Integration Board with a Siemens ROLM PBX. Pay attention

to set these features exactly (and assigned to the right keys) so that the PBX
Integration Board and the Dialogic

®

Unified API can function correctly.

• All PBX Integration Board ports on a ROLM system must be

programmed as ROLMphone 400 telephones.

• LINE must be programmed on Feature Key 09, and the ROLMphone

must be programmed to select this line when going off-hook.