beautypg.com

3 mnini, 4 mnine, Mnini – maintenance inhibit initiate – Dialogic SS7G2X User Manual

Page 87: Mnine – maintenance inhibit end, Mnini, Maintenance inhibit initiate, Mnine, Maintenance inhibit end

background image

87

Dialogic

®

SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.9.3

MNINI – Maintenance Inhibit Initiate

Synopsis

This command initiates the inhibiting of SS7 signaling. When specified without the INH parameter, the C7
signaling link is deactivated and no further signaling is allowed. When specified with

INHIBIT

=Y, the SS7 link

inhibit message is sent over the signaling link.

Syntax

MNINI:

C7LINK

=…;

MNINI:

C7LINK

=,

INHIBIT

=Y;

Prerequisites

When specified without the

INHIBIT

parameter, the SS7 links have been initiated and are uninhibited.

Attributes

CONFIG, PROMPT

Examples

MNINI:

C7LINK

=5;

Output Format

Inhibiting C7LINK 23
Inhibiting C7LINK 31
EXECUTED

6.9.4

MNINE – Maintenance Inhibit End

Synopsis

This command ends the inhibiting of C7 links. The C7 link is activated and signaling is allowed to proceed.
When specified without the

INHIBIT

parameter, the C7 signaling link is activated and signaling is allowed to

proceed. When specified with

INHIBIT

=N, the SS7 link uninhibit message is sent over the signaling link.

Syntax

MNINE:

C7LINK

=…;

MNINE:

C7LINK

=,

INHIBIT

=N;

Prerequisites

When specified without the

INHIBIT

parameter, the SS7 links have been initiated and are inhibited.

Attributes

CONFIG

Examples

MNINE:

C7LINK

=5;

Output Format

Uninhibiting C7LINK 23
Uninhibiting C7LINK 31
EXECUTED