Chapter 6 Command Definitions

6.4.6

ALREI – Alarm Reset Initiate

Synopsis

This command removes alarms that have cleared from the alarm log.

Attempts to remove commands that do not have the status CLEARED are rejected.

If parameter

ALP

is omitted, all alarms with status CLEARED are removed.

Syntax

ALREI[:

ALP

=];

Prerequisites

None

Attributes

None

Examples

ALREI:

ALP

=100;

ALREI;

6.4.7

ALTEI – Alarm Test Initiate

Synopsis

The command generates an active test alarm of the specified class, which is entered in the alarm log.

Alarm tests can be useful for validating the operation of hardware such as LEDS and alarm relays, as well as
ensuring proper communication with an SNMP manager without impacting the operation of the system.

Syntax

ALTEI:{[

CLA

=1]|[

CLA

=2]|[

CLA

=3]};

Prerequisites

Only one test alarm can be active at any one time. Test alarms can only be generated for classes 1, 2

and 3.

Attributes

None

Examples

ALTEI:

CLA

=3;