Chapter 6 Command Definitions

6.4.1

ALCLS – Alarm Class Set

Synopsis

This command assigns an alarm class value to a specified fault code(s).

The alarm class (

CLA

) is used to determine whether the alarm is classed as Minor, Major or Critical and in

turn governs the alarm LED, relay and SNMP alarm that are activated when the condition exists.

Each alarm code (

CODE

) has a factory-set default class. See

Chapter 8, “Alarm Fault Code Listing”

for the

factory default for each alarm code.

Syntax

ALCLS:

CLA

=,

CODE

=…;

Prerequisites

None

Attributes

CONFIG

Examples

ALCLS:

CLA

=1,

CODE

=20;

6.4.2

ALCLP – Alarm Class Print

Synopsis

This command gives a printout of the fault codes belonging to a particular alarm class. If the

CLA

parameter

is omitted, all fault codes are printed out.

Syntax

ALCLP[:

CLA

=];

Prerequisites

None

Attributes

None

Examples

ALCLP;
ALCLP:

CLA

=2;

Output Format

Alarm Fault Codes
CODE CLA TITLE
11 2 Processor1 fail
EXECUTED