beautypg.com

Table 9. alarm fault codes (continued) – Dialogic SS7G2X User Manual

Page 150

background image

150

Chapter 8 Alarm Fault Code Listing

Major

(MJR)

67

NIF err ind

Diagnostic event relating to the

Network Interface Function.

Persistent events of this type

should be reported to your support

representative.

NONE

2

Major

(MJR)

68

SNRT unavail

Reserved

SIG

NC

2

0

Major

(MJR)

69

C7RT unavail

One or more SS7 routes are

unavailable

SIG

NC

2

0

Major

(MJR)

70

AS unavail

One or more SIGTRAN Application

Servers are unavailable

SIG

NC

2

0

Major

(MJR)

71

AS under res

One or more SIGTRAN Application

Servers are available but have

insufficient number of ASP (load

sharing mode only)

SIG

NC

2

0

Major

(MJR)

73

M2PA event ind

Diagnostic event relating to the

M2PA protocol layer. Persistent

events of this type should be

reported to your support

representative.

NONE

2

Major

(MJR)

74

M2PA err ind

Diagnostic event relating to the

M2PA protocol layer. Persistent

events of this type should be

reported to your support

representative.

NONE

2

Minor

(MRN)

16

Alarm Test 1

This event indicates that the user

has invoked the alarm test for

alarm class 1 using the

ALTEI

command.

SYS

0

1

0

Minor

(MRN)

19

System Restart This event indicates the time at

which a system restart occurred.

SYS

0

1

0

Minor

(MRN)

34

New sync

source

The Signaling Gateway has

selected a new PCM as the clock

synchronization source.

PCM

PCM

1

Minor

(MRN)

79

Default alarm

The system has detected a low

priority low level alarm condition.

The user should contact their

support contact for further

information.

SYS

1

Table 9. Alarm Fault Codes (Continued)

Severity

(LED)

CODE

Name

Event Description

CATEGORY

ID

Class

DIAG

† The “Class” column provides the initial default setting of the alarm class for each fault code. The alarm class for any particular

alarm code is configurable using the

ALCLS

command and can be viewed using the

ALCLP

command. Changing the alarm class for

an event type changes the Severity indicated by the LEDs and/or relays.