beautypg.com

11 c7sle, 12 c7slp, 11 c7sle – ccs ss7 signaling link end – Dialogic SS7G2X User Manual

Page 75: 12 c7slp – ccs ss7 signaling link print, C7sle, Ccs ss7 signaling link end, C7slp, Ccs ss7 signaling link print

background image

75

Dialogic

®

SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.6.11

C7SLE – CCS SS7 Signaling Link End

Synopsis

This command is used to end an SS7 signaling link.

Syntax

C7SLE:

C7LINK

=;

Prerequisites

The signaling link must be blocked.

The signaling link must not be monitored.

Attributes

CONFIG

Examples

C7SLE:

C7LINK

=1;

6.6.12

C7SLP – CCS SS7 Signaling Link Print

Synopsis

This command is used to obtain a printout of the attributes of SS7 signaling link(s). If no link is specified, all
initialized links are output.

Syntax

C7SLP:[

C7LINK

=…];

Prerequisites

None

Attributes

None

Examples

C7SLP:

C7LINK

=1;

C7SLP;

Output Format

Signaling Link Configuration
C7LINK EQU TS SNLINK LS SLC M56K PCR
1 1-1 1-3-16 1 0 0 N
2 1-2 2-3-16 1 1 0 N
3 1 2 0 0 N
4 2 2 1 0 N
EXECUTED