Dialogic

®

SS7G2x Signaling Server SGW Mode User Manual Issue 4

PCM Traffic Measurements

Periodic reports conveying PCM performance data can be configured using the

RDPRI

command. PCMs are

associated with the report using the

RDPDI

command. PCMs can be removed from the report using the

RDPDE

command.

The

PRTYPE

parameter should be MSPCM.

SIGTRAN Link Traffic Measurements

Periodic reports conveying SIGTRAN link performance data can be configured using the

RDPRI

command.

SIGTRAN Links (

SNLINK

) are associated with the report using the

RDPDI

command. SIGTRAN Links can be

removed from the report using the

RDPDE

command.

The

PRTYPE

parameter should be MSSL.

Ethernet Port Traffic Measurements

Periodic reports conveying Ethernet performance data can be configured using the

RDPRI

command.

ETH

ports are associated with the report using the

RDPDI

command.

ETH

ports can be removed from the report

using the

RDPDE

command.

The

PRTYPE

parameter should be MSEP.

System Measurements

Periodic reports conveying system performance data can be configured using the

RDPRI

command. There are

no associated data types for use with this command.

The

PRTYPE

parameter should be MSSY.

9.5.4

Software Update

See

Section 4.11.1, “Software Update from a Remote Data Centre” on page 24

for example MML that

upgrades the Signaling Gateway software from an RDC.

9.5.5

Configuration Backup

See

Section 4.12.1, “Configuration Backup to Remote Data Centre” on page 25

for example MML that

upgrades the Signaling Gateway configuration from an RDC.

9.5.6

Configuration Update

See

Section 4.13.1, “Configuration Update from a Remote Data Centre” on page 26

for example MML that

upgrades the Signaling Gateway configuration from an RDC.

9.5.7

Software Option Installation

See

Section 4.14.3, “License Update from Remote Data Centre” on page 28

for example MML that installs

software options onto the Signaling Gateway from an RDC.