beautypg.com

1 stalp, 1 stalp – status alarm print, Stalp – Dialogic SS7G2X User Manual

Page 124: Status alarm print

background image

124

Chapter 6 Command Definitions

6.14.1

STALP – Status Alarm Print

Synopsis

This command requests an alarm status report summary. The interpretation of the ID field in the listing is
dependent on the alarm type (see

Chapter 8, “Alarm Fault Code Listing”

).

The fields have the following meanings:

SYS - The number of system alarms

PCM - The number of PCM alarms

SIG - The number of signaling alarms

CLA1 - The number of minor alarms

CLA2 - The number of major alarms

CLA3 - The number of critical alarms

Syntax

STALP;

Prerequisites

None

Attributes

None

Examples

STALP;

Output Format

Alarm Status

SYS PCM SIG CLA1 CLA2 CLA3
1 0 1 2 0 0
EXECUTED