beautypg.com

23 cntsp, 23 cntsp – configuration timeslot print, Cntsp – Dialogic SS7G2X User Manual

Page 62: Configuration timeslot print

background image

62

Chapter 6 Command Definitions

6.5.23

CNTSP – Configuration Timeslot Print

Synopsis

This command is used to print the configuration of all timeslots on a

PCM

.

A timeslot on a

PCM

can be allocated to signaling, voice, cross connect, monitoring or it can be unallocated.

Data is printed for a timeslot when it is acting as an outgoing timeslot.

A timeslot can act as an outgoing timeslot for the following types:

SIG - Carries signaling information. It forms a duplex connection.

OTS - Acts as an outgoing timeslot for a cross connection. It may form a duplex connection.

STS - The outgoing timeslot monitoring the send direction of an object.

RTS - The outgoing timeslot monitoring the receive direction of an object.

Note: An object is currently only a signaling link.

For signaling, the

STS

monitors information sent from the

EQU

of the signaling link and the

RTS

monitors

information received by the signaling link.

Syntax

CNTSP:

PCM

=;

Prerequisites

None

Attributes

None.

Examples

CNTSP:

PCM

=3-3;

Output Format

PCM Timeslot Configuration
TS TYPE C7LINK ITS
3-3-22 SIG 6
3-3-24 OTS 4-4-4
3-3-25 RTS 7
3-3-25 STS 8
EXECUTED