SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.5.21

CNTOS – Configuration Timeout Value Set

Synopsis

This command is used to change the value of a timer for a particular signaling system.

The user should specify the timer type (

TTYPE

), the timer itself (

TO

) and time that it should be set to,

expressed in either seconds (

TSEC

) or milliseconds (

TMSEC

).

Note: Some signaling system timer values are not changeable.

See the

CNTOP

command to verify timer values. See

Section 5.3, “Signaling Gateway Timers” on page 38

for

the definition of signaling system specific timers.

Syntax

CNTOS:

TTYPE

=,

TO

=,{

TSEC

=|

TMSEC

=};

Prerequisites

None

Attributes

CONFIG

Examples

CNTOS:

TTYPE

=MTP3,

TO

=7,

TSEC

=30;

6.5.22

CNTOP – Configuration Timeout Value Print

Synopsis

This command is used to print the value of either a single timer or all the timers for a particular protocol
module. (Refer to

CNTOS

command to set timer values.)

Syntax

CNTOP:

TTYPE

=,[

TO

=,];

Prerequisites

None

Attributes

None

Examples

CNTOP:

TTYPE

=MTP3;

Output Format

Timeout Values:
TTYPE TO TSEC TMSEC
MTP3 1 60
MTP3 2 360
MTP3 3 120
MTP3 4 360
MTP3 5 5
MTP3 6 5
MTP3 7 3
MTP3 10 60
EXECUTED