10 c7slc, 10 c7slc – ccs ss7 signaling link change, C7slc – Dialogic SS7G2X User Manual
Page 74: Ccs ss7 signaling link change

74
Chapter 6 Command Definitions
6.6.10
C7SLC – CCS SS7 Signaling Link Change
Synopsis
This command is used to change the attributes of an SS7 signaling link.
Syntax
C7SLC:
Prerequisites
•
The specified link has already been initiated.
•
The specified
time slot is not already assigned elsewhere in the system.
•
The
on which the timeslot exists has been initiated.
•
If specified, the board on which the
exists has been initiated.
•
If specified, the
on which the timeslot exists has been initiated.
•
The timeslot is a valid timeslot number for the
type (up to 31 for a E1 PCM and 24 for a T1 PCM).
•
The signaling processor specified by the
parameter must be equipped with a valid board type and
not already assigned to a link.
•
All links within the link set must be blocked.
•
parameters are specified the link must be blocked and C7 links
board must
be blocked. To change the other parameters on the C7 link, the link must be inhibited.
•
If
is set to either 1 or 2, all links on the same board for which M56K is set to 1 or 2 must also use
the same M56K value (that is, only one mode of 56kbits/s operation is supported on any board at one
time. However, it is possible for some links to operate at 64kbits/s, while others operate at 56kbits/s).
•
The signaling processor specified by the
parameter must be equipped with a valid board type and
not already assigned to a link.
•
All links within the link set must be blocked.
Note: After blocking, an SS7 link cannot be unblocked until all the boards processing the SS7 signaling
are blocked and then unblocked.
•
If the
parameters are specified, the link must be blocked and the C7 link’s EQU board
must be blocked. To change the other parameters on the C7 link, the link must be inhibited.
•
If
is set to 3 or 4, the
cannot be specified and if M56K is not set to 3 or 4, the
must be
specified.
•
Only
signaling processors 1 and 2 can be used if
•
is present, the
and
cannot be present.
•
must be M2PA.
•
is specified, it must be initiated, blocked and cannot be associated with any other SS7 link.
•
The command cannot change between
type C7LINKs.
•
SS7 links can use signaling processors 1 to 4 on a SPCI4 or SPCI2S board or 1 to 64 on a SS7HDP board.
Attributes
CONFIG
Examples
C7SLC: