Table 10. blower performance - 2 & 2.5 ton, Table 10, 208 volt operation – Reznor R8HE Unit Installation Manual User Manual
Page 29
29
R8HE / PPG3HE -X24K060XA / -X30K060XA
60,000 BTUH, 30” CABINET, 11”X8” BLOWER W- 3/4 HP ECM MOTOR
230 VOLT OPERATION
SWITCH
SETTINGS
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1
2
3
4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
0
0
0
0
824
64
782
67
740
71
697
76
653
81
611
86
568
93
529
100
489
108
1
0
0
0
894
59
852
62
810
65
766
69
722
73
681
78
640
82
601
88
562
94
0
1
0
0
964
55
922
57
880
60
836
63
791
67
752
70
712
74
674
78
635
83
1
1
0
0
1039
51
997
53
956
55
915
58
874
60
833
63
793
67
754
70
716
74
0
0
1
0
1113
47
1073
49
1032
51
995
53
957
55
915
58
873
60
835
63
797
66
1
0
1
0
1168
45
1128
47
1088
49
1051
50
1014
52
973
54
932
57
894
59
857
62
0
1
1
0
1222
43
1183
45
1144
46
1107
48
1070
49
1031
51
991
53
954
55
916
58
1
1
1
0 1283
41
1246
42
1209
44
1158
46
1107
48
1081
49
1054
50
1015
52
975
54
0
0
0
1
1343
39
1308
40
1273
41
1209
44
1144
46
1131
47
1117
47
1076
49
1034
51
1
0
0
1
1393
38
1358
39
1324
40
1273
41
1223
43
1196
44
1169
45
1128
47
1088
49
0
1
0
1
1443
37
1409
37
1374
38
1338
39
1301
41
1261
42
1220
43
1181
45
1142
46
1
1
0
1
1482
36
1446
37
1410
37
1374
38
1339
39
1300
41
1261
42
1223
43
1185
45
0
0
1
1
1521
35
1483
36
1445
37
1411
37
1376
38
1339
39
1301
41
1264
42
1227
43
1
0
1
1
1560
34
1522
35
1485
36
1450
36
1416
37
1378
38
1340
39
1303
40
1267
42
0
1
1
1
1598
33
1562
34
1525
35
1490
35
1455
36
1417
37
1379
38
1343
39
1306
40
1
1
1
1
1633
32
1595
33
1557
34
1524
35
1490
35
1458
36
1426
37
1390
38
1353
39
208 VOLT OPERATION
SWITCH
SETTINGS
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1
2
3
4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
0
0
0
0
783
67
740
71
696
76
645
82
594
89
554
95
514
103
472
112
429
123
1
0
0
0
851
62
808
65
765
69
719
73
672
79
631
84
590
90
549
96
509
104
0
1
0
0
919
57
877
60
834
63
792
67
750
70
708
75
665
79
627
84
588
90
1
1
0
0
994
53
953
55
913
58
871
61
830
64
785
67
741
71
702
75
664
79
0
0
1
0
1068
49
1030
51
991
53
950
56
909
58
863
61
816
65
778
68
740
71
1
0
1
0
1122
47
1084
49
1046
50
1005
53
964
55
920
57
876
60
837
63
797
66
0
1
1
0
1175
45
1138
46
1101
48
1060
50
1018
52
977
54
936
56
895
59
854
62
1
1
1
0 1237
43
1198
44
1159
46
1120
47
1082
49
1040
51
999
53
957
55
916
58
0
0
0
1
1299
41
1258
42
1216
43
1181
45
1146
46
1104
48
1061
50
1020
52
978
54
1
0
0
1
1349
39
1308
40
1267
42
1232
43
1197
44
1156
46
1115
47
1072
49
1030
51
0
1
0
1
1398
38
1358
39
1318
40
1283
41
1248
42
1208
44
1168
45
1125
47
1082
49
1
1
0
1
1440
37
1398
38
1357
39
1322
40
1288
41
1247
42
1206
44
1163
45
1121
47
0
0
1
1
1481
36
1439
37
1396
38
1362
39
1327
40
1285
41
1243
42
1202
44
1160
45
1
0
1
1
1516
35
1476
36
1436
37
1400
38
1365
39
1325
40
1285
41
1247
42
1209
44
0
1
1
1
1550
34
1513
35
1475
36
1439
37
1402
38
1365
39
1327
40
1292
41
1257
42
1
1
1
1
1581
33
1544
34
1507
35
1476
36
1444
37
1410
37
1375
38
1332
40
1289
41
NOTES:
1. Factory settings are in bold. Use of any other switch setting may result in nuisance trips and should be verified for the application.
2. Temperature rises in tables are approximate. Actual temperature rises may vary.
3. Shaded areas are not recommended or approved for proper heating operation of equipment.
Heat rise: Btu/h (Input) = CFM * Δ T * 1.08
Δ T = (Btu/h * 0.95) / (CFM * 1.08)
Table 10. Blower Performance - 2 & 2.5 Ton