Dehumidification options, Optional furnace control board connections, Electronic air cleaner – Reznor R8HE Unit Installation Manual User Manual

Page 14: Humidifier, Caution

background image

14

air-flow. Verify the selected rise is within the specification

shown on the furnace rating label or in the tables.

Dehumidification Options

The fixed speed motor control board has a

DEHUM

connection that allows the system to increase the amount

of humidity that is removed from the circulating air. This

is accomplished by reducing the CFM and allowing the

cooling coil to become colder. This function is only available

when there is a call for cooling. There are many ways this

function can be electrically wired.
When 24VAC is present at the

DEHUM terminal of the

blower control board the airflow requirements will be

reduced to approximately 75% of the nominal airflow

requirements. If the humidity level of the conditioned space

decreases during the cycle and the humidistat opens, the

airflow will be restored to 100% of the selected value.
• If the room thermostat incorporates a humidity sensor

and

DEHUM output, connect the DEHUM on the

thermostat to the

DEHUM terminal on the motor control

board. See

Figure 10 (page 36)

.

• If using a separate humidistat, connect the

DEHUM & R

terminals on the humidistat to the

DEHUM & R terminals

on the motor control board. In this option, the

DEHUM

output of the humidistat must be set to be normally open

and closed when there is a call for dehumidification.

If a humidistat is not available, it is an acceptable option

to directly jumper the

R & DEHUM on the blower control

board.

NOTE: This option will always operate the blower

at 75% the rated airflow for the first 10 minutes of every

cooling cycle no matter what the humidity level of the
home is. See

Figure 10

.

CAUTION:

To avoid personal injury or property damage,

make sure the motor leads do not come into

contact with any uninsulated metal components

of the unit.

O p t i o n a l F u r n a c e C o n t r o l B o a r d
Connections
Electronic Air Cleaner

The furnace control board provides output terminals

for an optional electronic air cleaner (EAC) that can be

installed in the return air duct of your system. The

EAC

output is energized any time the HEAT or COOL blower

speed is energized. Control ratings are 1.0 Amp. @ 240

VAC. Output connections are made via board terminals

labeled

EAC and NEUTRAL.

Humidifier

The furnace control board provides output terminals for

an optional humidifier (

HUM) that can be installed on

your system. The

HUM output is energized any time the

furnace inducer motor is energized. Control ratings are

1.0 Amp. @ 240 VAC. Output connections are made via

board terminals labeled

HUM and NEUTRAL.

Check all factory wiring to the proper unit wiring diagram:

Figure 13 (page 37)

,

Figure 14 (page 38)

, &

Figure 15

(page 39)

. Inspect the factory wiring connections and

make sure they didn’t loosen during shipping or installation.