2 preparing the furnace for installation, 0 dimensions and clearances, 1 dimensions – Reznor RPB Unit Installation Manual User Manual
Page 4: 0 uncrating and preparation (cont'd), 1 uncrating and inspecting (cont'd), 1 shipped-separate components
Form I-RPB, P/N 131782 R11, Page 4
4.0 Dimensions
and
Clearances
3.2 Preparing the
Furnace for
Installation
FIGURE 1 -
Dimensions,
Outdoor/ Power-
Vented Model
Series RPB
4.1 Dimensions
Size
A
B
C
D
Gas Connection
Natural Propane
125
inches
28-5/8
17-3/8
25-7/8
15-1/4
1/2
1/2
mm
727
441
657
387
13
13
150, 175
inches
34-1/8
22-7/8
31-3/8
20-3/4
1/2
1/2
mm
867
581
797
527
13
13
200, 225
inches
39-5/8
28-3/8
36-7/8
26-1/4
1/2
1/2
mm
1006
721
937
667
13
13
250
inches
47-7/8
36-5/8
45-1/8
34-1/2
1/2
1/2
mm
1216
930
1146
876
13
13
300
inches
47-7/8
36-5/8
45-1/8
34-1/2
3/4
1/2
mm
1216
930
1146
876
19
13
350
inches
53-3/8
42-1/8
50-5/8
40
3/4
1/2
mm
1362
1070
1286
1016
19
13
400
inches
58-7/8
47-5/8
56-1/8
45-1/2
3/4
1/2
mm
1470
1210
1426
1156
19
13
Air Openings:
Dimensions
Standard Horizontal Air Inlet
19-1/2 (495) x B
Optional Return Air Opening (bottom)
19-1/2 (495) x B
Standard Horizontal Discharge Air Opening
18 (457) x D
Optional Vertical Discharge Air Opening (w/Option AQ5 or AQ8 Plenum) 19-1/2 (495) x B
distributor. If you are an authorized Distributor, follow the FOB freight policy procedures
as published by Reznor for Reznor
®
products.
Check the rating plate for the gas specifications and electrical characteristics of the
furnace to be sure that they are compatible with the gas and electric supplies at the
installation site.
3.2.1 Shipped-Separate Components
Read this booklet and become familiar with the installation requirements of your par-
ticular furnace. If you do not have knowledge of local requirements, check with the local
gas company or any other local agencies who might have requirements concerning
this installation. Before beginning, make preparations for necessary supplies, tools,
and manpower.
Check to see if there are any field-installed options that need to be assembled to the
furnace prior to installation.
Option Parts - Some gas control options will have parts either shipped loose with the
heater or shipped separately. If your unit is equipped with any of the gas control options
in the table below, be sure these parts are available at the job site.
Other shipped-separate options could include a roof curb, a screened outside air hood,
a gas shutoff valve, a thermostat, a different control switch, a remote console, a manual
fan switch, a vertical vent terminal, a gas supply regulator, and/or a disconnect switch.
Or, if equipped with an optional evaporative cooling module, a water hammer arrestor
or fill and drain or freeze kit could be shipped separately.
3.0 Uncrating and
Preparation
(cont'd)
3.1 Uncrating and Inspecting (cont'd)
Application
Option Shipped Separate Components
Heating -- Gas Control AG7
Thermostat,
P/N 48033
Makeup Air -- Gas
Control Options
(NOTE: If an optional
remote console
is ordered, the
control switch and
temperature selector
may be mounted on the
console.)
AG3
Control Switch,
P/N 29054
AG8
Control Switch,
P/N 29054; Sensor & Mixing Tube,
P/N 48041
AG9
Control Switch,
P/N 29054; Remote Temperature
Selector,
P/N 48042; Sensor & Mixing Tube, P/N 48041
AG15
Control Switch,
P/N 29054; Remote Temperature
Selector,
P/N 115848; Stage Adder Module, P/N
115849; Discharge Air Sensor Holder, P/N 115850;
Discharge Air Sensor Holder Bracket,
P/N 213612
AG39 Remote Temperature Selector, P/N 174849;
Temperature Sensor,
P/N 133228; Mixing Tube,
P/N 90323