0 electrical supply and connections (cont'd) – Reznor RPB Unit Installation Manual User Manual

Page 26

background image

Form I-RPB, P/N 131782 R11, Page 26

7.0 Electrical Supply and Connections (cont'd)

7.3 Typical Wiring Diagrams (cont'd) (Refer to the diagram supplied with the furnace for

alternate controls or optional equipment details.)

& CAPACITOR

L1

L2

L1

F

L2

8

10

10

BL

R

R

R

BK

BK

BK

BK

BK

W

CR

R

17

BR

7

TERMINAL BLOCK --

HEATER COMPARTMENT

TERMINAL BLOCK --

BLOWER COMPARTMENT

11, 12, 13, F, L1 & L2

1, 2, 4, 6, 7, 8, 10,

12, 13, L1 & L2

2, 6, 7, 8, 10,

RPB SERIES AH2 OR AH3-AG2-CL22 DWG. #B-275073 REV. #1

IJB

OPTIONAL FIELD WIRING

OPTIONAL FACTORY WIRING

FACTORY WIRING

FIELD WIRING

TOTAL WIRE MINIMUM RECOMMENDED

LENGTH WIRE SIZE

150 FEET #18 GA.

250 FEET #16 GA.

350 FEET #14 GA.

FIELD WIRING

BLOWER MOTOR

CONTACTOR COIL

VENTER MOTOR

8

BL

COMBUSTION

PRESSURE

SWITCH

12

1

2

2

6

6

4

11

6

Y

Y

W

BK

Y

Y

Y

Y

Y

W

7

7

7

BK

BR

24

H

TD

H

BR

BR

W

22

H

TD

H

BR

7

BK

BL

W

7

TIME DELAY

RELAY COIL

13 - 28

17

FAN TD

HEATER

BR

R

R

LOW STAGE

PILOT

HIGH STAGE

12

Y

7 - 8 - 9

1/60 OR 3/60

LINE

GRD

G

R OR W

R OR BK

R

PROTECTED

BLOWER

MOTOR

INTERNALLY

CONTACTOR

BLOWER MOTOR

CONTACTS

L2

L3

L1

W

BK

BK

T1

T2

T3

13

O

13

LIMIT

AUTO RESET

REVERSE FLOW

UNIT AUTOMATIC

LIMIT CONTROL

COM

NC

NO

BK

Y

40 VA. CONTROL

TRANSFORMER

24V

BK

R

LINE VOLT

BR

Y

BL

BR

7

L2

L1

RH

TWO

ST

A

GE THERMOST

AT

OPTIONAL

W2

(ADD RH-RC

W1

RC

JUMPER)

HIGH S

TG

HI

PV

PIL

O

T

STG

LO

W

C

MV

REDUND

ANT

GAS V

AL

VE

HONE

YWELL T

WO

ST

A

GE

PIL

O

T

AL

TERNA

TE

W

.R. T

WO

ST

A

GE

REDUND

ANT

GAS V

AL

VE

R

BL

3

HIGH S

TG

4

BK

STG

2

LO

W

1

BR

(SEE NOTES)

DISCONNECT SWITCH

8

BL

BK

CONTACTS

FAN TD

1

3

WIRING CODE

BLACK - BK

BROWN - BR

ORANGE - O

YELLOW - Y

GREEN - G

BLUE - BL

PURPLE - PR

WHITE - W

RED - R

C

7

Y

BL

IGNITION

CONTROLLER

PROBE

GND

SPARK

FLAME SENSING

MV/PV

MV

SENSE

TH

PV

24V GND

BR

GND BURNER

G

BURNER

GROUND

BK

ON 115/460V. UNITS THE CONTROL TRANSFORMER IS A SINGLE VOLTAGE PRIMARY.

- ON 208/230V. UNITS THE CONTROL TRANSFORMER HAS A DUAL VOLTAGE PRIMARY.

- USE #12 GA. WIRE FOR LINE AND MOTOR WIRING ON SINGLE PHASE UNIT.

- USE #14 GA. WIRE FOR LINE AND MOTOR WIRING ON THREE PHASE UNIT.

TO PREVENT VOLTAGE DROP BEYOND FIVE PERCENT OF SUPPLY LINE VOLTAGE.

- LINE AND BLOWER MOTOR BRANCH CIRCUIT WIRE SIZE SHOULD BE OF A SIZE

A TEMPERATURE RATING OF AT LEAST 105 DEGREES C., EXCEPT FOR ENERGY

MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING

- CAUTION: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE

- DOTTED WIRING AND THE FOLLOWING CONTROLS ARE SUPPLIED AND INSTALLED

- THE FOLLOWING CONTROLS ARE SUPPLIED AS OPTIONAL EQUIPMENT:

- THE FOLLOWING CONTROLS ARE SUPPLIED BY REZNOR FOR FIELD INSTALLATION:

FOR 115/460V. UNITS USE BLACK AND YELLOW LEADS.

FOR 208V. UNITS USE BLACK AND RED LEADS (CAP YELLOW).

FOR 230V. UNITS USE BLACK AND YELLOW LEADS (CAP RED).

THERMOSTAT

CUTOFF OR SENSOR LEAD WIRE WHICH MUST BE 150 DEGREES C.

- USE #18 GA. WIRE FOR 24 VOLT CONTROL WIRING ON UNIT.

BY OTHERS: NONE

NONE

NOTE

USE DUAL ELEMENTS TIME DELAY FUSES AND SIZE ACCORDING TO 1.25

TIMES THE MAXIMUM TOTAL INPUT AMPS.

- WHEN PROVIDING OR REPLACING FUSES IN THE FUSIBLE DISCONNECT SWITCH

- DISCONNECT SWITCH IS FIELD FURNISHED OR AVAILABLE FROM FACTORY AS AN OPTION.

OPERATING SEQUENCE
- SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION, FAN SWITCH AT "AUTO" POSITION.

- TURN ON POWER AND MANUAL GAS VALVE TO UNIT.

- SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION, FAN SWITCH AT "AUTO" POSITION FOR SHUTDOWN.

- SET THERMOSTAT SYSTEM SWITCH AT "AUTO" POSITION, FAN SWITCH AT "AUTO" POSITION.

- FIRING RATE IS CONTROLLED BY THE THERMOSTAT.

- BLOWER MOTOR OPERATES FROM FAN TIME DELAY.

- BLOWER MOTOR REMAINS ON AS DETERMINED BY FAN TIME DELAY.

FIRING SEQUENCE:

- ON A CALL FOR HEAT BY THE LOW STAGE OF THERMOSTAT.

- THE VENTER MOTOR IS ENERGIZED AFTER A 15 SECOND (APPROX.)

TIME DELAY.

- VENTER FLOW SWITCH SWITCHES FROM N.C. TO N.O. CONTACTS ENERGIZING

FLAME ON EACH OPERATING CYCLE. THE SENSING PROBE PROVES THE

PRESENCE OF THE PILOT FLAME AND ENERGIZES THE SAFETY SWITCH

PORTION OF THE CONTROL. THE SWITCH ACTION DE-ENERGIZES THE

SPARK GAP AND ENERGIZES THE MAIN VALVE. THE MAIN GAS IGNITES

AND UNIT FIRES AT LOW RATE.

- ON A CALL FOR HEAT BY THE HIGH STAGE OF THE THERMOSTAT, THE

UNIT FIRES AT FULL RATE.

THE PILOT GAS VALVE AND SPARK GAP TO PRODUCE A PILOT

- IF THE FLAME IS EXTINGUISHED DURING MAIN BURNER OPERATION,

THE SAFETY SWITCH CLOSES THE MAIN VALVE AND RECYCLES THE

SPARK GAP.

ON UNITS EQUIPPED WITH LOCKOUT CONTROL, IF PILOT IS NOT

ESTABLISHED WITHIN 120 SEC. THE UNIT LOCKS OUT FOR ONE

HOUR, UNLESS IT IS RESET BY INTERRUPTING POWER TO
THE CONTROL CIRCUIT. (SEE LIGHTING INSTRUCTIONS)

M1(4)

M2(5)

RELAY CONTACTS

VENTER TIME DELAY

M3(1)

M4(3)

VENTER TIME DELAY

RELAY CONTACTS

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

31

32

33

FIGURE 28 - Typical Wiring Diagram for Model RPB, Outdoor, Power-Vented Furnace with Two-

Stage Gas Valve