A.B.S Function "A.B.S"
When the 3PKS is used with the Futaba fail safe unit (FSU-1), it will operate as de-
scribed below.
- When the FSU-1 is connected to the throttle channel, and the A.B.S. function has
been activated, the FSU-1 LED will flash each time the servo operates. The reason
for this is that the FSU-1 responds to sudden data changes caused by A.B.S. function
pumping operation. It does not mean that the fail safe function is activated. The servo
will not be affected.
Fail Safe Unit
- Basic setting
ABP: Approx. 30% (If this value is too high, the braking distance will increase.)
CYC: 5~7
DTY: 0 (When grip is low: - side, when grip is high: + side)
DLY: 10~15%
TH.P: Approx. 70%
STM: OFF
- When the wheels lock, or the car spins, when the brakes are applied fully
ABP: Increase from 30%
DTY: Shift from 0 to - side (-1, -2, -3)
DLY: Reduce the delay
- When the braking effect is poor and the braking distance is long when the brakes are
applied fully
ABP: Decrease from 30%
DTY: Shift from 0 to + side (+1, +2, +3)
DLY: Increase the delay
Example of A.B.S. function setting when S9451 / S9351 used
(There will be a slight difference depending on the state of the linkage.)