Ssg-mull-sill-install, Ssg mull - sill installation – Oldcastle BuildingEnvelope CW-250 User Manual
Page 47

SSG MULL - SILL INSTALLATION
47
February 2012
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
ANCHOR HOLES (NBV)
*NOTE: FACE OF HORIZONTALS AND
BUTT GLAZE MULLION DO NOT ALIGN
DUE TO STRUCTURAL
SILICONE SPACE REQUIREMENTS.
SEAL OFFSET AFTER ASSEMBLY.
*1/8"
DRILL 7/32" CLEAR HOLE AND
C'SINK 7/16" DIA. FOR #12 PFH
#17 (.173 dia) DRILL
THRU FOR #8 FASTENER
3/4"
9/16"
CW250-FP-2
TYP SEAL FACE
TO ASSEMBLY OF HORIZ
SHEAR BLOCK PRIOR
= D.L.O. -1/16"
HORIZ CUT LENGTH
FS-202
CW250-FP-86
MULL CAP
CAP SEAL
FS-323
CW-12
11/16"
CW-7
CW250-FP-86
MULL CAP
SHOWN
SEAL AS