90isc-glazing, 90 inside corner glazing – Oldcastle BuildingEnvelope CW-250 User Manual
Page 36

90 INSIDE CORNER GLAZING
O
36
February 2012
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
HORIZONTAL CUT LENGTH =
WORKPOINT + 5 17/32"
HEAD AND SILL CUT LENGTH =
HORIZ. LENGTH - 1/16".
CW-27
CW-36
FS-322
@ 18" O.C.
SEAL ADAPTORS @
BOTH ENDS & FULL
LENGTH
(SEE NOTE #1,SHT. 33)
SEAL END OF HORIZONTAL
AND ADAPTOR TO FACE OF
MULLION.
MARRY SEALANT AT ENDS OF HORIZ.
ADAPTOR TO END SEAL AND VERT.
ADAPTOR SEALS.
5 17/32"
(NTS)
1 1/8"
REF.
CW-3 PRESSURE PLATE
CW-2 FACE CAP
V2110
CW-17 GASKET
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L