LIVE LOAD SPLICE INSTALLATION
28
February 2012
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
SEAL BETWEEN MULL
AND SPLICE SLEEVES
NOTES:
1) APPLY BOND BREAKER TAPE
AS SHOWN IN DETAIL 1 FOR LIVE
LOAD SPLICES ONLY.
2) SEAL SPACES BETWEEN SPLICE AND
MULLION AS SHOWN IN DTL 1
3) CLEAN (& PRIME IF REQ'D) FOR
CURING-TYPE SEALANT BETWEEN MULL
HALVES. AS SHOWN
IN DETAIL 2.
APPLY BOND BREAKER
TAPE TO SPLICE AT
LIVELOAD SPLICES ONLY.
SEAL JOINT BETWEEN MULLS
AT FACE AND SIDES
DETAIL 1
DETAIL 2
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L