beautypg.com

90isc-fabrication, 90 inside corner fabrication – Oldcastle BuildingEnvelope CW-250 User Manual

Page 34

background image

90 INSIDE CORNER FABRICATION

O

34

February 2012

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

2 3/4"

1 11/16"

1 1/4"

CW-22

FS-43 (TYP)

FSW-324

@ HEAD &

SILL ANCHORS

ANCHOR HOLE (NBV)

#17 (.173 dia)

DRILL THRU FOR

#12 FASTENER

TOP OF

HORIZONTAL

CW250-FP-7

CW250-FP-14

CW250-FP-13 (OPP SIDE)

CW250-FP-13

CW250-FP-14 (OPP SIDE)

1 1/4"

1 1/4"

1 9/16"

REF.

CW250-FP-92 MULL CAP

USE TOP & BOTTOM OF

MULL. ATTACH W/ FS-202

REF. SHT. 33 FOR ATTACHMENT

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L