90 OUTSIDE CORNER GLAZING
O
33
February 2012
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
NOTE:
1) COMPLETELY SEAL BOTH ENDS OF ADAPTOR TO HORIZONTALS;
MARRY SEALANT TO ADAPTOR LONGITUDINAL SEALS TO GLASS
SEALS.
2) REFERENCE SHEETS 31 THRU 32 FOR SHEARBLOCK, ANCHOR AND HORIZONTAL
DETAILS.
1/2"
1/32"
(FACE CAP)
2 1/2"
1 3/16"
1 3/8"
1/2"
WEATHER SEALANT
CONTINUOUS SEAL BETWEEN
ADAPTOR & MULLION
FS-119
(#10 X 1 3/8" PFH
STS) @ 18" O.C.
CW-37
SEAL ADAPTORS @
BOTH ENDS & FULL
LENGTH (SEE NOTE #1)
CW-17 GASKET
(SQUARE, BUTT
ENDS)
CW-34
CW-31
W/ CW-6
CW-1636
NOTE:
HORIZONTAL CUT LENGTH =
WORKPOINT - 3 11/16"
HEAD AND SILL CUT LENGTH =
HORIZ. LENGTH - 1/16"
CW-2 FACE CAP
CW-3 PRESSURE
PLATE
1/8"
(PRES. PLT.)
FS-322
@ 12" O.C.
CW-17
3 11/16"
NOTE: HORIZONTAL
FLUSH TO FACE
OF MULL
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L