135isc-assembly, 135 inside corner assembly – Oldcastle BuildingEnvelope CW-250 User Manual
Page 41
135 INSIDE CORNER ASSEMBLY
O
41
February 2012
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
CW-164
w/ CW-6
CW-165
CW-161
CW-23
CW-12
CW-12
CW-1
FS-42 (TYP)
CAP SEAL
NOTE:
DO NOT USE CW-13 OR CW-14
HORIZONTALS AT CORNERS.
3/4" TYP.
FS-322 @ 12" O.C.
SEAL TYP.
3/4"
DRILL 7/32" CLEAR HOLE AND
C'SINK 7/16" DIA. FOR #12 PFH.
USE HOLES IN HORIZONTAL TO
MATCH DRILL (#17 (.173 dia) HOLES
IN SHEAR BLOCKS.
*
*
CW250-FP-51
CW250-FP-50 (OPP SIDE)
CW250-FP-52 (TYP)
CW250-FP-50
CW250-FP-51 (OPP SIDE)
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L