beautypg.com

Door-subframe-install, Door frame assembly - sub-frame at threshold – Oldcastle BuildingEnvelope CW-250 User Manual

Page 23

background image

DOOR FRAME ASSEMBLY - SUB-FRAME AT THRESHOLD

23

February 2012

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

FS-322 (#12 X 1" HHSTS)

@ 18" O.C.

FS-42

TH-44 CLIP

TH-43

FG-2145

CW-20 DOOR JAMB

BED DOOR JAMB

IN SEALANT

BED THRESHOLD

IN SEALANT

SET DOOR JAMB IN SEALANT

AT SILL AND MARRY INTO

THRESHOLD & PRIMARY WEATHERSEAL.

CW-3 CUT 1/4" SHORT

AT SILL. SEE NOTE 2

NOTES:

1) CW-20 DOOR JAMB TO RUN THRU AT

SILL TO FINISHED FLOOR

2) CW-3 PRESSURE PLATE TO BE CUT

1/4" SHORT AT SILL FOR WEEPAGE.

CW-1 MULLION

CAP SEAL FASTENERS

C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L