Door-subframe-install, Door frame assembly - sub-frame at threshold – Oldcastle BuildingEnvelope CW-250 User Manual
Page 23
DOOR FRAME ASSEMBLY - SUB-FRAME AT THRESHOLD
23
February 2012
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
FS-322 (#12 X 1" HHSTS)
@ 18" O.C.
FS-42
TH-44 CLIP
TH-43
FG-2145
CW-20 DOOR JAMB
BED DOOR JAMB
IN SEALANT
BED THRESHOLD
IN SEALANT
SET DOOR JAMB IN SEALANT
AT SILL AND MARRY INTO
THRESHOLD & PRIMARY WEATHERSEAL.
CW-3 CUT 1/4" SHORT
AT SILL. SEE NOTE 2
NOTES:
1) CW-20 DOOR JAMB TO RUN THRU AT
SILL TO FINISHED FLOOR
2) CW-3 PRESSURE PLATE TO BE CUT
1/4" SHORT AT SILL FOR WEEPAGE.
CW-1 MULLION
CAP SEAL FASTENERS
C W - 2 5 0 C U R T A I N W A L L I N S T A L L A T I O N M A N U A L