Door-no-subfrm-install, Door frame assembly at head & jamb - no sub-frame – Oldcastle BuildingEnvelope CW-250 User Manual
Page 24

DOOR FRAME ASSEMBLY AT HEAD & JAMB - NO SUB-FRAME
24
February 2012
CW-151 PRESSURE PLATE
CUT LENGTH = DOOR OPENING
+ 1 1/2". BED IN SEALANT
AT SILL.
CW-151 PRESSURE PLATE
CW-150 FACE CAP
CW-3 PRESSURE PLATE
CW-2 FACE CAP
BUTT TO CW-150
FACE CAP BELOW
FS-322 @ 12" O.C.
CW-150 FACE CAP
CUT LENGTH = DOOR
OPENING + 2 1/2" -
SEALANT JOINT @ SILL
DRILL 1/2" ACCESS HOLE IN
CW-151 AND INSTALL FS-43
@ 12" O.C.
APPLY CONTINUOUS
SEALANT BEFORE
INSTALLATION
CW-1