Also, Chapter 5.9 alarm button – AVer NX8000 User Manual
Page 66

59
- Enable/disable
the
Alarm Message
check box, to active with external alarm
message by your own program. For the detail configuration, please contact the local
reseller.
- Enable/disable
the
Alarm Button
check box, to active manual alarm function (see
). To define alarm message of manually alarm trigger. Click
alarm button and select the alarm button # and fill in the description of alarm button.
Once the Alarm button has been activated and defined, the Alarm button will display
on Advanced UI.
-
Continue trigger duration:
Set a time period that when sensor has been trigger
and stay in the same status for that period, then the alarm will be sent out.
6. In
(5) Alarm Reset
, click the camera number (use W and X to select the alarm) to set the
reset condition of alarm. Once alarm is reset, all alarm action will stop at the moment. If
the sensor normal status is high, set the sensor condition to low.
Click IP Cam Sensor to IP camera sensor reset condition. Click High or Low column to
set the reset condition of alarm.
7. In
(6) Action
, you may now set the alarm action for the system to perform when the alarm
condition is activated.
-
Launch E-Map
Display mini Emap screen.
-
TV Out
Switch to only display the video on TV from where the alarm is activated or selected
camera.
-
Enlarge Camera View
Switch to only display video in Preview/Advanced mode from where the alarm is
activated.
-
Relay Output
Set to enable/disable the relay operation when the alarm is activated and to extend