beautypg.com

8 the sensor input and relay output specifications, 9 connecting pos (point of sales), The sensor input and relay output specifications – AVer NX8000 User Manual

Page 16: Connecting pos (point of sales), B. relay output specification, C. coil ratings (at 20 oc ), D. contact ratings, 9 connecting pos (point of sales) avermedia

background image

9

2.8

The Sensor input and Relay output Specifications

You may use the sensor input and relay output specifications table below for your reference.

A. Sensor

Input Specification

Absolute Maximum Ratings

(Ta=25°C)

Parameter Symbol

Rating

Unit

Forward Current

I

F

50 mA

Reverse Voltage

V

R

6 V

Input

Power Dissipation

P

70

mW

Electrical/Optical Characteristics

(Ta=25°C)

Parameter Symbol

Min

Typ.

Max.

Unit

Conditions

Forward Current

V

F

- 1.2

1.4 V

I

F

=20mA

Reverse Voltage

I

R

- - 10 A

V

R

=4V

Input

Terminal Capacitance

C

t

- 30

250

pF

V=o,

f=1KHz

Parameter Symbol

Min

Typ.

Max.

Unit

Conditions

Collector Dark Current

I

CEO

- - 100 nA

V

CE

=20V

Collector-Emitter
Breakdown Voltage

BV

CEO

35 -

-

V

I

C

=0.1mA

O

utput

Emitter-Collector
Breakdown Voltage

BV

ECO

6 - - V

I

E

=10 A

*Current

Transfer

Ratio CTR 50 - 600 %

Collector Current

I

C

2.5 - 30 mA

I

F

=5mA, V

CE

=5V R

BE

=

Collector-Emitter
Breakdown Voltage

V

CE(sat)

- 0.1 0.2 V

I

F

=20mA, I

C

=1mA

Isolation Resistance

R

ISO

5 x 10

10

10

11

-

DC500V, 40-60% R.H.

Floating Capacitance

C

f

- 0.6

1.0

pF

V=0,

f=1MHz

Cut-off Frequency

f

c

- 80 KHz

V

CE

=5V, I

C

=2mA

R

L

=100, -3dB

Response Time (Rise)

t

r

- 4

18 s

T

rans

fer

Char

ac

ter

is

tic

s

Response Time (Fall)

t

f

- 3

18 s

V

CE

=2V, I

C

=2mA

R

L

=100

I

C

*CTR=

I

F

100%

B. Relay

Output

Specification

Surge strength

:1500 VAC

Nominal power

: 200mw ~ 360mw

Operating power

: 110mw ~ 200mw

C. COIL RATINGS (at 20 oC )

Coil Nominal Voltage

(VDC)

Coil Resistance

10%

Pick-up Voltage

(VDC)

Drop-Out Voltage

(VDC)

Nominal Current

(mA)

5

125

3.75

0.5

40

* Max Continuous Voltage at 20

o

C : 110% of Coil Nominal Voltage

D. CONTACT

RATINGS

Contact Arrangement

1 Form C (SPDT)

max. Switch Power

max. Switch voltage

max. Switch current

125VA 60W

125VAC 30VDC

1A

Contact Resistance

≤ 100mΩ

Resistive Load

1A/125VAC

1A/30VDC

2.9

Connecting POS (Point of Sales)

AVerMedia

®

AVerDVR can be integrated with POS system equipment. Connecting the POS

equipment to AVerMedia

®

AVerDVR system thru RS232 connection, enables you to view,

record and keep track of the items that were sold. You may also select the camera on where to
display all the data. To connect, locate the RS232 port of the POS equipment and PC. Use an
RS232 cable (not supplied) to make the connection.