AVer IWH5000 series User Manual
Page 161

153
3. Mark the Enable check box to setup the condition.
4. Sensitive: Set the system detects sensitivity.
5. Delay Time: Set the lasting time for system to detect the object.
6. Use the mouse to click and drag the frame on the screen.
Maximum_Object: the maximum detect size. The objects are out of the maximum
detect area will be disregard. Use mouse to click and drag the frame on the screen.
Minimum_Object: the minimum detect area. When the objects are smaller than the
minimum detect area, the system will disregard. Use mouse to click and drag the
frame on the screen.
7. Enable Mask: Mark an area on the screen to disregards the motion in the marked area
and to only monitor outside the marked area. Mark the Enable Mask check box, click and
drag the mask frame on the screen.
8. To reset all object frames, click Clean. To clean an object frame, click right button of
mouse and drag the object frame that user want to clean
-
Scene Change
When the camera has been moved, the system will alarm.
1. Select the camera number and press right button on the mouse to call up the setup
windows. And then, click the Scene Change Tab.
2. Click Save to capture the image for comparing reference. To view the captured image,
enable the Show Reference Image check box. The captured image will display on screen.
The reference image is sharing with the Missing Object and Suspicious Object function.
3. Mark the Enable check box to setup the condition.
4. Sensitive: Set the system detects sensitivity.
5. Delay Time: Set the lasting time for system to detect the movement.
6. Change Rate: Set the camera movement range which compare with the original position.
7. Enable Mask: Mark an area on the screen to disregards the motion in the marked area
and to only monitor outside the marked area. Mark the Enable Mask check box, click and
drag the mask frame on the screen.