HP 38g Graphing Calculator User Manual
Page 181
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Extremum
Function
Contains the last value found by Extremum operation in the
Plot-FCN menu.
FastRes
Toggles resolution between plotting in every other column
(faster), or plotting in every column (more detail).
Solve
From Plot Setup, choose Faster or More Detail.
or
In a program, type
1 {{STOl^}}FastRes for faster (default).
0 {{STO^}}FastRes for more detail.
Grid
Turns the background grid in Plot View on or off.
From Plot Setup, check (or uncheck) _
grid
.
or
All Aplets
In a program, type
1 {{STO^}}Grid to turn the grid on.
0 {{STO^}}Gr id to turn the grid off (default).
Hmin/Hmax
Defines minimum and maximum values for histogram bars.
From Plot Setup for one-variable statistics, set value for HRNG.
or
Statistics
In a program, type
n
{{STO^}}Hmin
n
{{STO^}}Hmax
Hwidth
Sets the width of histogram bars.
In a program, type
Statistics
n
{{STO^})Hwidth
Indep
Defines the value of the independent variable used in Tracing
mode.
In a program, type
All Aplets
n
{{STO^-})lndep
Programming 8-29