Adding a master valve – Baseline Systems BaseStation 6000 User Manual
Page 25

P a g e
| 17
Adding a Master Valve
Any single valve biCoder can be used to operate a master valve. A master valve biCoder can be used to actuate a master valve.
1. On the Main Page of the BaseStation 6000 software, click
the Remote Base Unit that the master valve biCoder is
connected to.
2. Click the Config Zone
(1)
tab.
3. In the Serial Number column, type the serial number for
the master valve biCoder in an unused address line
(2)
.
Note: The serial number of the two-wire biCoder is
located on the side of the unit. The serial number for the
powered biCoder is located on the inside of the
enclosure door.
4. Press Enter on your keyboard. The system searches for
the device, tests the master valve and the
communication, and then displays the Configuration
Status message box.
5. Click OK.
6. Type a description of the master valve biCoder in the Description
(3)
field. Use the description to define the location or area
that this master valve is controlling.
7. Click the arrow in the Device Mode
(4)
field, and then click one of the following options to define the mode of the master
valve:
• M-Valve – Used for a normally closed master valve that turns on when the flow zone is activated
• M-Val NO – Used for a normally open master valve
8. In the Flow Zone Number
(5)
field, type the number of the flow zone that this master valve controls. Refer to Setting Up
Flow Monitoring for Flow Zones on page 61.